General Purpose Power Supply (GPDPS) 6 Device PowerSupply
System Reference, January 2001
151
If you further increase the load capacitance, the initial
voltage ripple will be reduced but voltage ringing may
appear. See also the example “Measurement in Perfor-
mance Range 2 with High Load Capacitance” on
page 153.
Figure64 Measurement Block Diagram
Measurement in Performance Range 1
Figure 65 Load regulation in performance range 1
DPS
C
R
i
Scope
i
[V]
20 mA –> 0
0 –> 20 mA
[s]
U = 4.5 V
C = 100 nF
0 <–> 20 mA