9.4 Multi-axis systems
9.4.1 Station address for CAN-bus
During setup it makes sense to use the keypad on the front panel to preset the station
addresses for the individual amplifiers and the baud rate for communication (ð p.79).
9.4.2 Baud rate for CAN-bus
After changing the station address and baud rate you must turn the 24V auxiliary
supply for the servo amplifier off and on again.
Coding of the Baud rate in the LED display :
Coding Baud rate in kbit/s Coding Baud rate in kbit/s
1 10 25 250
2 20 33 333
5 50 50 500
10 100 66 666
12 125 80 800
100 1000
9.5 Keypad operation / LED display
This section illustrates the two possible operating menus and the use of the keys on the
front panel. Normally, the SERVOSTAR 300 only presents the standard menu for your
use. If you want to operate the amplifier via the detailed menu, you must keep the right
key pressed while switching on the 24V supply.
9.5.1 Keypad operation
The two keys can be used to perform the following functions:
Key symbol Functions
press once : move up one menu item, increase number by one
press twice in rapid succession : increase number by ten
press once : decrease number by one
press twice in rapid succession : decrease number by ten
hold right key pressed, and then press left key as well :
to enter a number, “Return” function