8.17.4.2 Control circuit
The example shows a circuit diagram with two separated work areas connected to one
emergency stop circuit. For each work area individually "safe stop" of the drives is swit
-
ched by a protective screen.
The safety switchgears used in the example are manufactured by Pilz and fulfill at least
the safety category 3 according to DIN 954-1. Further information to the safety switchge
-
ars is available from Pilz. The use of safety switchgears of other manufacturers is possi
-
ble, if these also fulfill the safety category 3 according to DIN 954-1.
Consider the wiring instructions on page 60.
SERVOSTAR
®
300 Product Manual 63
Kollmorgen 09/2006 Electrical installation
Emergency-stop circuit acc.
to EN 954-1 category 4
Safe stop acc. to EN954-1 category 3 for 3 drives
Safe stop acc. to EN 954-1 category 3 for 2 drives