8.13 Master-slave operation, encoder master control
This interface can be used to link several SERVOSTAR 300 amplifiers together in mas
-
ter-slave operation.
Parameter setting for the slave amplifier is carried out with the aid of the setup software
(electrical gearing). The resolution (no. of pulses/turn) can be adjusted, and the analog
setpoint inputs are out of action.
Signal diagram (for encoders with RS422 or 24 V output)
8.13.1 Connection to a SERVOSTAR master, 5 V signal level (X5)
This interface can be used to link several SERVOSTAR 300 amplifiers together in mas-
ter-slave operation. Up to 16 slave amplifiers can be controlled by the master, via the
encoder output. The SubD connector X5 is used for this purpose.
Frequency limit: 1.5 MHz, transition time tv £ 0.1 µs
54 SERVOSTAR
®
300 Product Manual
Electrical installation 09/2006 Kollmorgen
SERVOSTAR 300