6.4.6 Permissible ambient conditions, ventilation, mounting position
Storage hints
ð p.13
Transport hints
ð p.13
Supply voltage
Auxiliary voltage
without brake and fan
with brake or fan
303-310*: 1x110V
-10%
…1x230V
+10%
, 50/60 Hz
3x110V
-10%
…3x230V
+10%
, 50/60 Hz
341-346*: 3x208V
-10%
- 3x 480V
+10%
, 50/60 Hz
20VDC...30VDC
24 V DC (-0% +15%), check voltage drop !
Ambient temperature in operation
0...+40°C under rated conditions
+40...+55°C with power derating 2.5% / °C
Humidity in operation
rel. humidity 85%, no condensation
Site altitude
up to 1000 meters a.m.s.l. without restriction
1000…2500 meters a.m.s.l. with power derating
1.5% / 100meters
Pollution level Pollution level 2 as per IEC 60664-1, 2.5.1
Enclosure protection IP 20
Mounting position
vertical ð p.29
Ventilation 1 A and 3 A types
all other types
natural convection
built-on fan
Make sure that there is sufficient forced ventilation within the control cabinet.
* order code reference see p. 106
6.4.7 Conductor cross-sections
Following EN 60204, we recommend for single-axis systems:
AC connection 1.5 mm² (14awg) 600V,105°C
DC bus link
Regen resistor
1.5 mm² (14awg)
1000V, 105°C,
shielded for lengths
>20cm
Motor cables up to 25 m 1 - 1.5 mm² (14awg)
600V, 105°C, shielded,
capacitance <150pF/m
Motor cables 25m to 50 m,
with motor choke 3YLN
1 mm² (14awg)
600V,105°C, shielded,
capacitance <150pF/m
Resolver, motor thermostat
4x2x0,25 mm² (22awg),
max. 100m
twisted pairs, shielded,
capacitance <120pF/m
Encoder, motor thermostat 7x2x0,25 mm² (22awg), max.50m twisted pairs, shielded
ComCoder, Thermoschutz 8x2x0,25 mm² (22awg), max.25m twisted pairs, shielded
Setpoints, AGND 0.25 mm² (22awg) twisted pairs, shielded
Control signals, BTB, DGND 0.5 mm² (20awg)
Holding brake (motor) min. 0.75 mm² (18awg)
600V, 105°C, shielded,
check voltage drop
+24 V / DGND max. 2,5 mm² (12awg) check voltage drop
For multi-axis systems, observe the specific operating conditions for your system.
To reach the max. permitted cable length, observe cable requirements ð p. 35.
* Danaher Motion North America supplies cables up to 39 meters
* Danaher Motion Europe supplies cables up to max. length
6.5 LED display
A 3-character LED display indicates the status of the amplifier after switching on the 24V
supply (ð p.79). When the keys on the front panel are used, the parameter and function
numbers are shown, as well as the numbers for any errors that may occur (ð p.80).
22 SERVOSTAR
®
300 Product Manual
Technical description 09/2006 Kollmorgen